122
RL5000 S
ERIES
XS
CALE
AND
X2 A
UTOMATED
T
ELLER
M
ACHINES
S
ERVICE
M
ANUAL
Section 3
C
OMMON
SDD F
AULTS
WITH
P
OSSIBLE
C
ORRECTIONS
N
O
OR
I
NCORRECT
R
ESPONSE
FROM
THE
SDD
1. SDD is not switched on or power supply fault.
2. Interface cable not connected or broken.
3. Logic 0V lines not connected at power supply.
4. Check link LK6 is set correctly.
5. SDD crashed. Switch off SDD and switch on again or apply hard reset; fault
should clear.
6. Dispenser Fault
M
OTOR
K
ICKS
AND
T
IMING
W
HEEL
E
RROR
IS
R
EPORTED
1. Timing wheel sensor/cable faulty. Check sensor/connections.
2. The 36V power supply has dropped below 34V.
3. There is too much light shinning on the Timing Wheel Sensor.
4. Dispenser Fault
N
OTHING
H
APPENS
AND
T
IMING
W
HEEL
E
RROR
IS
R
EPORTED
1. The 36V power supply is not connected.
2. The transport motor is disconnected. Check connections.
3. Fuse FS2 or FS3 has blown. Replace fuse (4A quick blow, 125V, 5x20mm).
4. The 36V power supply is in excess of 38V.
5. Dispenser Fault
T
HE
F
EED
M
OTOR
D
OES
N
OT
T
URN
BUT
‘F
EED
F
AILURE
’ I
S
R
EPORTED
1. The feed motor is disconnected. Check connections.
2. Fuse FS1 has blown. Replace fuse (4A quick blow, 125V,5x20mm).
3. Dispenser Fault
T
HE
F
EED
M
OTOR
K
ICKS
P
ERIODICALLY
BUT
D
OES
N
OT
G
IVE
N
ORMAL
1/3 (A
PPROX
.)
R
EVOLUTION
F
EED
C
YCLES
.
1. The feed sensor is blocked or faulty.
2. Dispenser Fault
Summary of Contents for RL5000
Page 2: ...ii RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL...
Page 14: ...xiv RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Preface...
Page 19: ...2 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 1...
Page 21: ...4 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 1...
Page 29: ...12 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 2...
Page 51: ...34 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 3...
Page 162: ...145 INDEX Index INDEX...