Controls Interface
around to the header of the report. When the first item of a report is
displayed and the Previous key is pressed, the display will wrap around to the
last item.
Selected Setpoint Report
The first three keys on the second row - Operator Settings, Service Settings
and Service Tests - allow the operator to adjust various setpoints and perform
various tests. Certain items in these groups are password protected. Refer to
the Password section for additional information.
When a setpoint key is press, a header will be displayed. The setpoint
headers identify the available items and setpoint functions.
The Next and Previous keys function in the same manner as that describe in
Selected Report Group, above.
Setpoint values are incremented by pressing the plus
key and decre-
mented by pressing the Minus
key. Once a setpoint is changed, the
Enter key must be pressed to save the new setpoint. If the Cancel key is
pressed, the setpoint value on the display will be ignored and the original
setpoint will remain.
Passwords
Passwords are needed to enter into the Service Setup Menu and the
Machine Configuration Menu. Both of these menus are accessed through the
Service Settings key. If access into these menus is necessary, follow the list
of steps below:
1.
Press Service Settings.
2.
Press Next until the readout in the display is:
Password Required For Further Access
“Please enter Password”
3.
To enter into the Service Setup Menu, press:
Enter
4.
To enter into the Machine Configuration Menu, press:
Enter
Select Report Group and Select Settings Group Flowcharts
The first block of the flowchart is the header which is shown on the display
after the menu key is pressed. For example:
Press Chiller Report and the readout on the display will be:
CHILLER RPRT:STATUS, WTR TEMPS & SETPTS
“PRESS (NEXT) (PREVIOUS) TO CONTINUE”
Press Next to move down through the Chiller Report. As shown in the
figures, the flowchart explains the conditions that the UCM looks at to
determine which readout is to be displayed next. For example:
Press Chiller Report to display the header Press Next to display
MODE:
OPERATING MODE]
REQUESTED SETPOINT SOURCE:
[SETPT SOURCE]
Press Next to display
COMPRESSOR ON
CIRCUITS LOCKED OUT
Press Next to display
Summary of Contents for R Series
Page 17: ...RLC SVX07A EN 17 Installation Mechanical Figure 2 Rigging and Lifting for RTWA Units ...
Page 22: ...22 RLC SVX07A EN Installation Mechanical Figure 7 Rigging and Lifting for RTUA Units ...
Page 25: ...RLC SVX07A EN 25 Installation Mechanical Figure 10 Rigging and Lifting for RTCA Condenser ...
Page 69: ...RLC SVX07A EN 69 Installation Electrical Figure 28 Interconnecting Wiring from RTUA to RTCA ...
Page 129: ...RLC SVX07A EN 129 Start Up Procedures Figure 41 RTWA Unit Sequence of Operation ...
Page 130: ...130 RLC SVX07A EN Start Up Procedures Figure 42 RTUA Unit Sequence of Operation ...
Page 154: ...154 RLC SVX07A EN Diagnostics ...
Page 156: ...156 RLC SVX07A EN 3332 ...
Page 158: ...158 RLC SVX07A EN 3333 ...
Page 160: ...160 RLC SVX07A EN 3334 ...
Page 162: ...162 RLC SVX07A EN 3335 ...
Page 164: ...164 RLC SVX07A EN 3336 ...
Page 166: ...166 RLC SVX07A EN 5119 ...
Page 168: ...168 RLC SVX07A EN 5143 ...
Page 170: ...170 RLC SVX07A EN 5144 ...
Page 172: ...172 RLC SVX07A EN 5145 ...
Page 174: ...174 RLC SVX07A EN 5146 ...
Page 176: ...176 RLC SVX07A EN 6008 ...
Page 178: ...178 RLC SVX07A EN 6009 ...
Page 180: ...180 RLC SVX07A EN 5147 ...
Page 182: ...182 RLC SVX07A EN 6526 ...
Page 184: ...184 RLC SVX07A EN 5150 ...
Page 186: ...186 RLC SVX07A EN 6010 ...