![TP-Link T2500G-10MPS User Manual Download Page 183](http://html1.mh-extra.com/html/tp-link/t2500g-10mps/t2500g-10mps_user-manual_1145700183.webp)
Configuring DDM
DDM Configuration
Configuration Guide
159
Step 4
show ddm configuration
voltage
Display the DDM voltage threshold of the SFP ports.
Step 5
end
Return to Privileged EXEC Mode.
Step 6
copy running-config startup-config
Save the settings in the configuration file.
The following example shows how to set SFP port 1/0/9’s high alarm threshold voltage as 5
V.
Switch#configure
Switch(config)#interface gigabitEthernet
1/0/9
Switch(config-if)#ddm vlotage_threshold
high_alarm 5
Switch(config-if)#show ddm configuration
voltage
Voltage Threshold(V) :
High Alarm Low Alarm
High Warning
Low Warning
Gi1/0/9 5.000000
--
--
--
Gi1/0/10
--
--
--
--
Switch(config-if)#end
Switch#copy running-config startup-config
2.2.5 Configuring Bias Current Threshold
Follow these steps to configure the threshold of the DDM bias current on the specified SFP
port.
Step 1
configure
Enter global configuration mode.
Step 2
interface { fastEthernet
port
| range fastEthernet
port-list
|
gigabitEthernet
port
| range
gigabitEthernet
port-list
| ten-gigabitEthernet
port
| range ten-gigabitEthernet
port-list
}
Enter interface configuration mode.
Summary of Contents for T2500G-10MPS
Page 1: ...User Guide T2500G 10MPS 1910012405 REV1 0 1 April 2018...
Page 24: ...Using the CLI 767 Appendix Default Parameters 773...
Page 145: ...Part 5 Monitoring Traffic CHAPTERS 1 Traffic Monitor 2 Appendix Default Parameters...
Page 172: ...Part 7 Configuring DDM CHAPTERS 1 Overview 2 DDM Configuration 3 Appendix Default Parameters...