71
8-3-2. Specifications of IF-60GP
GP-IB section
Specifications
Conforms to IEEE488-1978.
Interface functions
SH1, AH1, T6, L4, SR1, RL1, PR0, DC1, DT0, C0, & E1
Address setting
Address between 1 and 30 may be set freely.
Delimiter
LF, EOI, & LF + EOI
Listener function
Output conditions of controlled power supply units may
be set.
Talker function
Output conditions and setting conditions of controlled
power supply units may be detected.
Service request function
Occurrence of alarms and errors and presence or
absence of responses are reported.
Q
’ty of connectable units
Maximum of 14 units are connectable with a single
GP-IB card.
Local bus section
Specifications
Conforms to the RS-485 Standards. Exclusive protocol.
Max. cable length
10 [m]
Connector type
RJ-11 (6-pin modular)
Pin 2 (D+), pin 3 (D-)
Applicable cable
Exclusive modular cable
CB-0603S, -0615S, -0630S & -06100S
Q
’ty of connectable units
Maximum of 10 units are connectable through daisy
chain connection.
Terminator
Built-in. May be turned on/off with jumper pin.
Q
’ty of ports
2 ports, non-directional
※
The IF-60RU and IF-60GP have the same local bus for the slave
units, which may be equipped with either type of interface boards.