39
(2) Press the
ENTER
/
CHECK
key to enter the sequence operation setting
mode. Select ON or OFF with the encoder.
(The sequence operation is set to OFF before shipment.)
initial setting
Sequence operation activated
(3) Press the
ENTER
/
CHECK
key to validate setting.
The LED below the PRESET key goes on.
1 2 3
○ ○ ○
― ●
SEQUENCE
―
(4) Set an intended start step number with the encoder.
Press the
ENTER
/
CHECK
key to validate it.
The setting range is from 0 to 99.
Starting sequence operation from step No.
“00”
(5) Then, set an intended end step number with the encoder.
Press the
ENTER
/
CHECK
key to validate it.
The setting range is from 0 to 99.
Finishing sequence operation at step No.
“99”