110
Constant-Voltage Characteristics
PSF-1200L
PSF-1600L
Source fluctuation
※
5
0.01% ±2mV of rated voltage
Load fluctuation
※
6
0.01% ±3mV of rated voltage
Ripple noise (p-p)
※
7
150mV
Ripple noise (rms)
※
8
6mV
Transient response (typ.)
※
9
2ms
Rise time (typ.)
※
10
50ms (rated load), 50ms (no load)
Fall time (typ.)
※
11
100ms (rated load)
5000ms (no load)
100ms (rated load)
2000ms (no load)
Temperature coefficient (typ.)
※
12
±50ppm/ºC (after 30-minute warming up)
Constant-Current Characteristics
PSF-1200L
PSF-1600L
Source fluctuation
※
5
0.01% ±2mA of rated current
Load fluctuation
※
13
0.02% ±3mA of rated current
Ripple noise (rms)
120mA
Temperature coefficient (typ.)
※
12
±100ppm/ºC (after 30-minute warming up)
Constant-Power Characteristics
PSF-1200L
PSF-1600L
Source fluctuation
※
5
0.5%±10W
NOTES
※
5
:
Fluctuation when the source voltage is changed by ±10% in the range from
AC100V to 240V.
※
6
:
Fluctuation when
the load is changed from the rated load into no load (open
circuit) at the rated output voltage.
※
7
:
Measured at the frequency up to 20 MHz.
※
8
:
Measured at the frequency up to 1 MHz.
※
9
:
Response time till the output voltage is restored to the range within 0.1% +
10 mV of the rated output voltage when the output current is changed from
50% to 100% of the maximum output current at the rated output voltage.
※
10
:
Value with a fixed load.
Time until the output voltage increases up to 10% to 90% of the rated output
voltage.
※
11
:
Value with a fixed load.
Time until the output voltage decreases down to 90% to 10% of the rated
output voltage.
※
12
:
Value after 30 minutes of warming up (excluding external control).
※
13
:
Fluctuation when the load is changed from the rated load into no load (short
circuit) at the rated output current.