34
(3) Press the
ENTER
/
CHECK
key. All PRESET keys blink.
Press the button of an intended PRESET key.
Only the pressed key is lit, the value is stored, and the normal state
is restored.
5-5-2. OVP/OCP function (02)
■
OVP
:
(Over Voltage Protection)
The OVP function turns off output when the output voltage of the
PSF Series exceeds the preset OVP value.
The setting range is from 1.0V to 84.0V. The resolution is 0.1V.
■
OCP
:
(Over Current Protection)
The OCP function turns off output when the output current of the
PSF Series exceeds the preset OCP value.
The setting range is from 1.0 A to 42.0 A (800L: 1.0 A to 84.0 A).
The resolution is 0.1 A. The resolution is different in one-control
parallel operation.
◆
See Section 2
“SPECIFICATIONS”.
(1) Press the
MENU
key until menu number
“02” is displayed.
(2) Every press of the
ENTER
/
CHECK
key alternates OVP and OCP
setting displays. On the PSF-400L2, OVP and OCP setting
display of the channel A appears first, which changes into OVP and
OCP setting display of the channel B then.
OVP setting
OCP setting
→
OVP and OCP setting of channel A
OVP and OCP setting of channel B