5-7-4. Constant-current (CC) control with external voltage or resistance
It is possible to control the output current by external voltage or
external resistance through the connector J3 (EXT CONT) on the rear
panel if external control is selected in Section
“5-5-6. External control
(external voltage, external resistance)
” above. For the setting
procedures, see Section
“5-5-6. External control (external voltage,
external resistance)
”.
CHA
:
Pins 15 and 16 (COM)
CHB
:
Pins 6 and 7 (COM)
1
2
25
26
EXT CONT 「J3」
Negative output
terminal of CHA
0V~
10V
0
Ω
~
10k
Ω
CHA
External control
※
Use a shielded cable or twisted pair wires for this control.
1
2
25
26
EXT CONT 「J3」
Negative output
terminal of CHB
0V~
10V
0
Ω
~
10k
Ω
CHB
External control
※
Use a shielded cable or twisted pair wires for this control.
Output current
FS
10V
External voltage
Output current
FS
10k
Ω
External resistance
Fig.5-16 External Voltage/Resistance Control Terminals (CC)