8
Protective functions
Over-voltage protection
(OVP): Fixed
※
15
Output Off when output voltage exceeds 110% of
rated voltage.
Over-voltage protection
(OVP): Variable
※
16
Presettable in range from 1V to 84V on front panel.
Output Off when OVP works.
Over-current protection
(OCP): Fixed
※
15
Output Off when output current exceeds 110% of
rated current.
Over-current protection
(OCP): Variable
※
16
Presettable in range from 1A to 42A on front panel.
Output Off when OCP works. (800L:84A)
Overheat protection (OHP)
※
15
Output Off at the internal heat sink temperature over
the set temperature.
NOTES
※
15
:
Throw the POWER switch again to reset.
※
16
:
Throw the POWER switch again or press the ESC key to reset.
Environmental Conditions
Operating temperature range
0ºC to +40ºC
Operating humidity range
30% RH to 80% RH (No dew condensation)
Storage temperature range
-20ºC to +70ºC
Storage humidity range
30% RH to 80% RH (No dew condensation)
Applicable Standards
LVD
EN61010-1 3rd edition (2010)
Indoor use
Altitude up to 2000m
Transient overvoltage: Overvoltage category II
Pollution Degree 2
EN61000-3-2 clause 7.1 class A
EN61000-3-3 clause 5.
EMC
EMS
(
Min
)
EN61326-1
:
2013
EMI
(
Class A
)
EN61326-1
:
2013
※
The standards are applicable for the product marked CE on the rear panel only
and not for the modified product.
The PSF-1200L / 1600L and the master slave mode does not apply.
Others
Cooling method
Forced cooling with fan motor
To-GND voltage
±DC500V
Dielectric strength voltage
Power In terminals - frame: AC1500V, 1min.
Power In terminals - output terminals: DC3200V, 1min.
Insulation resistance
Power In terminals - frame: DC500V, 30M
Ω
or more
Power In terminals - output terminals:
DC500V, 30M
Ω
or more
Output terminals - frame: DC500V, 30M
Ω
or more
Outside dimensions
(Projections not included.)
210mm(W)
×
124mm(H)
×
290mm(D)
Weight
PSF-400L: Approx. 5kg
PSF-800L, 400L2 & 800LS: Approx. 7kg