24
Screw (M6)
Washer
Nut
Terminal block
Output terminal bar
Fig.5-1 Connection with Rear Output Terminals
※
Connect the cables using the bolts supplied with the product as
shown above. If other bolts are used, they may get into contact
with the protective cover. The lug terminals must be outside the
output terminals.
(3) Connect positive or negative output terminal with the GND
screw with the
mark using the GND cable supplied with the
product as the necessity requires.
※
The negative potential of the external voltage control is the
same as that of the negative output terminal. If the power
supply unit is grounded at the positive terminal and the power
source for external control is grounded at the negative terminal,
the load cables for external voltage control short-circuits the
output of the power supply unit, resulting in troubles. Use the
power source for external voltage control in the floating
condition.
Connect with this screw
Fig.5-2 Positive Grounding Connection