8-5. Connection cables
・
Use the exclusive modular cables for local bus connection.
(Our product Nos.:CB-0603S,CB-0615S,CB-0630S & CB-06100S)
・
Use GP-IB cables obtainable on the market for GP-IB connection.
(Our product No.: CB-2420P)
・
Use USB cables (applicable to the full speed or superior)
obtainable on the market for USB connection.
・
Use interlink cables for Personal computers for RS-232C connection.
The pin assignment is as shown below. Note that the normal cross
cables may not be used.
Personal computer
IF-60RU
D-Sub
9 pin Male
2
RxD
<
-
>
3
D-Sub
9 pin Male
Inch screw
3
TxD
<
-
>
2
4
DTR
<
-
>
6
5
GND
<
-
>
5
6
DSR
<
-
>
4
7
RTS
<
-
>
8
8
CTS
<
-
>
7
FG
<
-
>
FG
Fig.8-2 RS-232C Cable Connection
8-6. Address Setting
The interface has two addresses: Personal computer address, and
system address. It depends on the address whether the unit serves as
the master unit connected with a Personal computer or a slave unit
connected with the local bus. If the system address of a unit is set to 1,
that unit serves as the master unit, whose Personal computer address
may be specified. Assign different numbers to all slave units connected
with a single master unit.
※
The system address of the unit directly connected with a Personal
computer must be 1.
※
The system operation is not guaranteed if several slave units
connected with the master unit have the same system
address.
Do not assign the same address to several slave units.