Constantly monitors the battery voltage and automatically

selects one of four operating modes:

NORMAL • BOOST • STORAGE • DESULFATION

Computer Controlled Charging System

The Intelligent way to charge and maintain your vehicle’s battery.

45 AMP 

 60 AMP 

 80 AMP

Summary of Contents for KIPS12-45

Page 1: ... OWNERS MANUAL Constantly monitors the battery voltage and automatically selects one of four operating modes NORMAL BOOST STORAGE DESULFATION Computer Controlled Charging System The Intelligent way to charge and maintain your vehicle s battery 45 AMP 60 AMP 80 AMP ...

Page 2: ... have been shorted If this condition should occur the converter first limits the cur rent Should the condition continue to exist the converter then reduces the current output within thousandths of a second The Kinetik Intelligent Power Converter was designed to protect itself Once the short circuit has been corrected the converter will automatically return to normal operating conditions THERMAL PR...

Page 3: ...built in This is a microprocessor controlled device which constantly monitors the battery and then automatically adjusts the converter output volt age based on its charge status There are four 4 operating Modes NORMAL BOOST STORAGE and DESULFATION EQUALIZE Each mode is automati cally selected by the microprocessor and ensures a fast yet safe recharge for your battery See the chart below for detail...

Page 4: ...for a battery or other filtering NOTICE At normal input voltages the full load rated capacity is available At input voltages less than 105 VAC the converter may not supply full rated output capacity The full rated load is available for load battery charging or both When functioning as a regulated battery charger the Kinetik converters have a nominal voltage output of 13 6 VDC The system was design...

Page 5: ...etik Intelligent Power Converters are not designed for zero clear ance compartments Unobstructed ventilation is required ATTENTION 1 USE A 5 32 HEX DRIVER TO TIGHTEN THE OUTPUT SCREWS DO NOT EXCEED 50 IN LB TORQUE 2 THE OUTPUT TERMINALS ARE RATED FOR 2 TO 14 GA COPPER OR ALUMINUM WIRE 3 THE KINETIK INTELLIGENT POWER CONVERTERS ARE NOT WEATHER TIGHT OR DESIGNED FOR WET LOCATION MOUNTING THEY MUST B...

Page 6: ... Hook Up Correct Hook up and replace Fuses with same type and rating 3 Converter cycles on off Compartment gets too hot Check air flow to the con verter Improve Ventilation to the compartment 4 Low Output Excessive Load for Converter Reduce load requirements or Install Larger Converter Input Voltage not be tween 105 130 VAC Correct input supply voltage Bad Battery Cell s Replace Battery 5 Intermit...

Page 7: ...0 Watts Output 13 6 VDC 60 Amps Dimensions 3 6H x 9 15L x 9W Weight 5 8lbs KINETIK KIPS12 80 Input 105 130 VAC 60 Hz 1300 Watts Output 13 6 VDC 80 Amps Dimensions 3 6H x 11 65L x 9W Weight 7 5lbs CAUTION RISK OF FIRE Chassis bonding wire must be a separate wire ran directly from the Grounding Lug provided on the side of the converter DO NOT connect Output Negative to chassis using the same wire ...

Page 8: ...OFITS LOST SAVINGS LOSS OF USE OF ENJOYMENT OR F OTHER INCIDENTAL DAMAGES ARISING OUT OF THE USE OF OR INABILITY TO USE THE PRODUCT THIS INCLUDES DAMAGES TO PROPERTY AND TO THE EXTENT PERMITTED BY LAW DAMAGES FOR PERSONAL INJURY THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE PROOF OF PURCHASE A warranty claim m...