12
■
Default Setting and Storage after Power Off
Default Setting List of PSF Series
Item
Initial setting
Storage after
power off
Voltage
0.00V
○
Current
0.00A
○
Power
410W/820W
○
OVP
84.00V
○
OCP
42.00A/84.00A
○
Display mode
CHA(V/A)
○
Menu display
Initialized when power is turned off.
×
Operation mode
V
○
External voltage control
OFF
○
External resistance control
OFF
○
External output on/off
IN
○
Preset function
OFF
○
Preset item: Voltage
0V
○
Preset item: Current
0A
○
Preset item: Power
410W/820W
○
Off-timer function
OFF
○
High-impedance function
OFF
○
High-impedance holding time
30min
○
Delay function
OFF
○
Trailing delay time
0
○
Falling delay time
0
○
Tracking function
OFF
○
Sequence function
OFF
○
Sequence start No.
0
○
Sequence end No.
99
○
Sequence repetition frequency
1
○
Sequence item: Voltage
0V
○
Sequence item: Current
41.00A/82.00A
○
Sequence item: Power
410W/820W
○
Sequence item: Output
OFF
○
Sequence item: Time
1sec
○
Key lock function
OFF
×
One-control operation
OFF
○
Output status
Initialized when power is turned off.
×
Sequence operation status
×
(Stop status)
×
Off-timer operation status
×
(Non operating status)
×
System address
1
○
Personal computer address
3
○