Quad Link input configuration.
NOTE.
All four SDI inputs must be connected to a cable on the back of the
instrument to use the Quad Link Input Configuration.
1.
Select the
Settings
icon (
) to open the Settings menu.
2.
Select
Inputs
to open the Inputs submenu.
3.
Select an SDI input.
4.
Confirm that Quad Link cables are connected to the back of the instrument.
o
Quad Link A is connected to SDI-IN 1
o
Quad Link B is connected to SDI-IN 2
o
Quad Link C is connected to SDI-IN 3
o
Quad Link D is connected to SDI-IN 4
5.
Select
Quad Link
for the Input Configuration. SDI 1-4 (Link A-D) is
selected by default. (See
Figure 28
.)
Figure 28: Quad Link SDI signal configuration
NOTE.
The Quad Link and UHD/4K Mode buttons are only available when software
option MP2-FMT-4K is present.
6.
Use the
UHD/4K Mode
buttons to select
Auto
,
Sq Div
(Square Division) or
2
SI
(Two Sample Interleave).
NOTE.
In AUTO mode, the instrument defaults to Two Sample Interleave mode if
the Video Payload Identifier (VPID) complies with SMPTE 425.3 or SMPTE
425.5. The instrument defaults to Square Division mode if the VPID complies with
SMPTE 292.1, SMPTE 372, SMPTE 425.1, or a quad-HD signal is present and
VPID is missing. VPID in the signal is required for this option to operate properly.
7.
Select
Save
and close the menu.