PRISM MPI2-25 and MPX2-25 Media Analysis Platform User Manual
47
Configure IP stream inputs
To configure an IP stream:
1.
Select the
Settings
icon (
) to open the Settings menu.
2.
Select
Inputs
to open the Inputs submenu.
3.
Select the input from the list.
4.
Select
IP
. (See
Figure 33
.)
Figure 33: IP input protocols
Configure ST2022.
If you will be monitoring ST2022 streams, use these steps:
1.
Select
ST2022-6
.
2.
Slide the ST2022-7 Seamless Switching
control to
Enabled
or
Disabled
.
NOTE.
There is a difference between “Port” and “Path”. The Port is the physical
SPF port that is used to input the 10/25GE signal. Path 1 and Path 2 are the
signal paths to be used for seamless switching. This differentiation is being made
since it is possible for both Path 1 and Path 2 to use a single Port.
NOTE
:
With ST2022-7 seamless switching, a reconstructed output stream is
created from the two input streams. The reconstructed stream is used downstream
for various display tiles like Picture. The buffer size to absorb the packet
reception time difference between Path1 and Path2 is 10ms. The output stream
reconstruction will not work properly for streams on Path1 and Path2 with skew
greater than 10ms. This error makes tiles show the wrong images and
information.