PRISM MPI2-25 and MPX2-25 Media Analysis Platform User Manual
90
3.
On the application bar select the Capture icon. A screenshot is saved to the
device. (See
Figure 80
.)
Figure 80: Application bar – Capture
Take a stream capture
1.
Verify there is a USB stick connected to the PRISM monitor.
2.
Select the Settings
icon.
3.
From the Settings menu, select
Capture
.
NOTE.
If the Capture configuration menu does not appear under the Settings
menu, option MP2-IP-MEAS is not installed and stream captures are disabled.
4.
Select
Screenshot and Stream
under SELECT CAPTURE TYPE. (See
Figure 81
.)
5.
Use the
Port to Capture
drop-down menu to select from inputs 10/25GE
SFP
1
or
2
.
NOTE.
When capturing on a port configured for 25 Gb data rate, the maximum
total bitrate on the port must be less than 15 Gbps. Data packets captured in
the PCAP file may be dropped if the total bitrate exceeds this limit.
Figure 81: Selecting Screenshot and Stream