PRISM MPI2-25 and MPX2-25 Media Analysis Platform User Manual
49
system management software to discover, register, configure the input, and
select the active input for monitoring.
NOTE.
NMOS Discovery and Registration must be enabled in the network settings
for this control to be available.
(See Enable NMOS discovery and registration.)
3.
Slide the ST2022-7 Seamless Switching
control to
Enabled
or
Disabled
.
NOTE.
For ST2022-7 Seamless Switching, the two Path 1 and Path 2 streams
should be identical. If the streams are not identical, error messages are shown in
the Status Bar.
There is a difference between “Port” and “Path”. The Port is the physical SPF
port that is used to input the 10 GbE signal. Path 1 and Path 2 are the signal paths
to be used for seamless switching. This differentiation is being made since it is
possible for both Path 1 and Path 2 to use a single Port.
NOTE
:
With ST2022-7 seamless switching, a reconstructed output stream is created
from the two input streams. The reconstructed stream is used downstream for
various display tiles like Picture. The buffer size to absorb the packet reception
time difference between Path1 and Path2 is 10ms. The output stream
reconstruction will not work properly for streams on Path1 and Path2 with skew
greater than 10ms. This error makes Picture tiles show the wrong image.
4.
To configure the Video (2110-20)
stream tab:
a.
Move the Enable Video slider to
Enabled
to begin configuration. (See
Figure 35
.)
Figure 35: Enable a ST2110-20 video stream
b.
Enter the information in SFP Port, Source Addr, Source Port,
Destination Addr., and Destination Port for each video stream.
c.
Set the RTP Payload Type
between 96 and 127.