background image

SG-System 5

Installation Guide

For the full Installation Manual visit www.dsc.com

NOTE: This manual contains information regarding product use and function, in addition to manufacturer liability and

restrictions pertaining to it. The entire manual should be read carefully.

Summary of Contents for SG-System 5

Page 1: ... the full Installation Manual visit www dsc com NOTE This manual contains information regarding product use and function in addition to manufacturer liability and restrictions pertaining to it The entire manual should be read carefully ...

Page 2: ...undant configuration using two SG CPM5s where the primary SG CPM5 backs up to the secondary SG CPM5 and vice versa Under normal conditions the primary SG CPM5 is active and outputs all signals to the printer and automation while the secondary SG CPM5 is in standby If the primary fails the secondary SG CPM5 automatically switches to active within 30 seconds and starts outputting signals to the prin...

Page 3: ... 8A max RMS 100VAC Input current 250W 3A max RMS 100VAC Backup power supply External UPS not supplied In a two SG CPM5 configuration a redundant SG PSU5 can be inserted in the second slot In the event of a SG PSU5 failure the redundant SG PSU5 automatically assumes operation These modules are hot swappable can be removed and replaced while the system is in operation if a working redundant SG PSU5 ...

Page 4: ...IP line card shall be set to 60 min for single path and to 6 h for multiple path performance based technologies UL864 programming requirements NOTE Users Installers Authorities having Jurisdiction and other involved parties this product incorporates field programmable soft ware In order for the product to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarm...

Page 5: ...ons the UL Listed SG System 5 Console software can be used with the SG System 5 NOTE For ULC Listed applications the Console Printer application is considered supplemental and is only allowed to be used in con junction with a compatible ULC Listed printer SG System 5 Console software system requirements Compatible operating systems l Microsoft Windows 2008 Server 32 and 64 bit l Microsoft Windows ...

Page 6: ...r connection see note 10 Primary SG CPM5 display connection NOTE Employ only 26 AWG wires for the Telco connections NOTE The power cord must be routed inch away from all other cables coming from or which are part of the SG System 5 SG System 5 PSTN loading capacity of hunt groups Number of lines in hunt group System loading at the supervising station 1 2 3 4 5 8 Number of initiating circuits NA 50...

Page 7: ...nce that temporary discontinuance of service may be required But if advance notice is not practical the Telephone Company will notify the customer as soon as possible Also you will be advised of your right to file a com plaint with the FCC if you believe it is necessary Changes in Telephone Company Equipment or Facilities The Telephone Company may make changes in its facilities equipment operation...

Page 8: ...outed so that they do not come in contact with burrs cooling fan or heat sinks which could cause damage to the insulation of conductors Holes in metal shall have smooth well rounded surfaces or shall be protected with bushings The external enclosure shall be connected to the protective earth ground The external cabinet rack must be secured to the building struc ture before operation in a such a wa...

Page 9: ...placed at DSC s option Products not covered by this warranty or otherwise out of warranty due to age misuse or damage shall be evaluated and a repair estimate shall be provided No repair work will be performed until a valid purchase order is received from the Customer and a Return Merchandise Authorisation number RMA is issued by DSC s Customer Service Digital Security Controls s liability for fai...

Page 10: ...ULA and provided the recipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC may terminate this EULA if You fail to comply with the terms and conditions of this EULA In such event You must destroy all copies of the SOFTWARE PRODUCT and all of it...

Page 11: ......

Page 12: ...ademarks not owned by Tyco are the property of their respective owners and are used with permission or allowed under applicable laws Product offerings and specifications are subject to change without notice Actual products may vary from photos Not all products include all features Availability varies by region contact your sales representative 2020 Tyco Security Products All rights reserved Johnso...

Reviews: