3.0  Approvals

- 4 -

For UL listed installations, the equipment must be installed in accordance with the requirements of NFPA72, NFPA70, UL827 and the authority having
jurisdiction.
SG-System 5 with SG-DRL5-IP Line Card is ULC listed for active communication channel security level A1 - A4 when used in conjunction with T-
Link TL250 and T-Link TL300(CF), TL260(R), TL280LE(R), LE2080(R), TL280(R)E, TL880LT, TL880LE, LE9080, 3G9080, HS3128/032/248,
LE4010(CF), LE4020(CF), and 3G4010(CF) Internet/Intranet and/or GSM-GPRS alarm communicators. For this type of application the supervision
and encryption features have to be enabled. The receiver can be used also in conjunction with ULC listed passive communication systems based on the
configuration of the systems at the protected premises.
For ULC Installations the equipment must be installed in accordance with the requirements of ULC-S561 and ULC-S301 Standards and the authority
having jurisdiction. SG-System 5 with SG-DRL5/DRL5E/DRL5-2L PSTN line cards is ULC listed for passive communication channel security levels
P1-P3 when used in conjunction with compatible alarm systems using Industry Open SIA standard communication formats Contact ID or SIA.
This product has been approved by the California State Fire Marshal (CSFM) pursuant to section 13144.1 of the California Health and Safety Code.
See CSFM Listing No. 7300-1273:0157 for allowable values and/or conditions for use concerning material presented in this document. The approval is
subject to reexamination, revision and possible cancellation.
For ULC-S304 applications, the heartbeat timer (option [411]) shall be set to 30 seconds.
For UL864 Commercial Fire applications the following compatible communicators can be used with receiver model SG-System 5 SW Ver. 1.1x:
LE4010/LE4010CF SW Ver. 5.x
LE4020/LE4020CF SW Ver. 4.x
3G2010CF SW Ver. 4.x
TL300/TL300CF SW Ver. 1.5
The transmitter supervision (option [221] in SG-DLR5-IP line card) shall be set to 60 min for single path and to 6 h for multiple path performance
based technologies.

UL864 programming requirements

NOTE: Users, Installers, Authorities having Jurisdiction and other involved parties; this product incorporates field programmable soft-

ware. In order for the product to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarms
Systems, UL 864, certain programming features or options must be limited to specific values or not used at all as indicated below.

SG-CPM5 - UL864 programming requirements

Opt #

Program option

Permitted in UL864? (Y/N) Possible settings Settings permitted (UL 864)

202

Buzzer

N

Enabled/Disabled

Enabled

411

Heartbeat Timer

Y

00-FF

Not Allowed 00

601

CPM5 1 Fan Trouble

N

Enabled/Disabled

Enabled

602

CPM5 2 Fan Trouble

N

Enabled/Disabled

Enabled

603

PSU 1 Trouble

N

Enabled/Disabled

Enabled

604

PSU 2 Trouble

N

Enabled/Disabled

Enabled

609

UPS AC 1 Trouble

N

Enabled/Disabled

Enabled

610

UPS AC 2 Trouble

N

Enabled/Disabled

Enabled

611

UPS Battery 1 Trouble

N

Enabled/Disabled

Enabled

612

UPS Battery 2 Trouble

N

Enabled/Disabled

Enabled

615

SG-Serial Automation Sec 1 Trouble

N

Enabled/Disabled

Enabled

617

Serial CPM 1 Printer 1 Trouble

N

Enabled/Disabled

Enabled

618

Serial CPM 2 Printer 1 Trouble

N

Enabled/Disabled

Enabled

619

Serial CPM 1 Printer 2 Trouble

N

Enabled/Disabled

Enabled

620

Serial CPM 2 Printer 2 Trouble

N

Enabled/Disabled

Enabled

621

SG-TCP Automation Pri - Trouble

N

Enabled/Disabled

Enabled

631

SG-TCP Automation Sec - 1 Trouble

N

Enabled/Disabled

Enabled

665

TCP Printer Pri - 1 Trouble

N

Enabled/Disabled

Enabled

675

TCP Printer Sec - 1 Trouble

N

Enabled/Disabled

Enabled

SG-DRL5-IP

Opt #

Program option

Permitted in UL 864 (Y/N)

Possible

settings

Settings permitted (UL 864)

221

Transmitter Absent Debounce Time

Y

5-65535

3600 sec (1 h)/ 21600 sec (6 h)

222

Transmitter Restoral Debounce Time

Y

5-65535

200

301

Transmitter Unencrypted Trouble

N

Enabled/Disabled

Enabled

302

Unknown Account Trouble

N

Enabled/Disabled

Enabled

303 Supervised Accounts Exceeded Trouble

N

Enabled/Disabled

Enabled

Summary of Contents for SG-System 5

Page 1: ... the full Installation Manual visit www dsc com NOTE This manual contains information regarding product use and function in addition to manufacturer liability and restrictions pertaining to it The entire manual should be read carefully ...

Page 2: ...undant configuration using two SG CPM5s where the primary SG CPM5 backs up to the secondary SG CPM5 and vice versa Under normal conditions the primary SG CPM5 is active and outputs all signals to the printer and automation while the secondary SG CPM5 is in standby If the primary fails the secondary SG CPM5 automatically switches to active within 30 seconds and starts outputting signals to the prin...

Page 3: ... 8A max RMS 100VAC Input current 250W 3A max RMS 100VAC Backup power supply External UPS not supplied In a two SG CPM5 configuration a redundant SG PSU5 can be inserted in the second slot In the event of a SG PSU5 failure the redundant SG PSU5 automatically assumes operation These modules are hot swappable can be removed and replaced while the system is in operation if a working redundant SG PSU5 ...

Page 4: ...IP line card shall be set to 60 min for single path and to 6 h for multiple path performance based technologies UL864 programming requirements NOTE Users Installers Authorities having Jurisdiction and other involved parties this product incorporates field programmable soft ware In order for the product to comply with the requirements in the Standard for Control Units and Accessories for Fire Alarm...

Page 5: ...ons the UL Listed SG System 5 Console software can be used with the SG System 5 NOTE For ULC Listed applications the Console Printer application is considered supplemental and is only allowed to be used in con junction with a compatible ULC Listed printer SG System 5 Console software system requirements Compatible operating systems l Microsoft Windows 2008 Server 32 and 64 bit l Microsoft Windows ...

Page 6: ...r connection see note 10 Primary SG CPM5 display connection NOTE Employ only 26 AWG wires for the Telco connections NOTE The power cord must be routed inch away from all other cables coming from or which are part of the SG System 5 SG System 5 PSTN loading capacity of hunt groups Number of lines in hunt group System loading at the supervising station 1 2 3 4 5 8 Number of initiating circuits NA 50...

Page 7: ...nce that temporary discontinuance of service may be required But if advance notice is not practical the Telephone Company will notify the customer as soon as possible Also you will be advised of your right to file a com plaint with the FCC if you believe it is necessary Changes in Telephone Company Equipment or Facilities The Telephone Company may make changes in its facilities equipment operation...

Page 8: ...outed so that they do not come in contact with burrs cooling fan or heat sinks which could cause damage to the insulation of conductors Holes in metal shall have smooth well rounded surfaces or shall be protected with bushings The external enclosure shall be connected to the protective earth ground The external cabinet rack must be secured to the building struc ture before operation in a such a wa...

Page 9: ...placed at DSC s option Products not covered by this warranty or otherwise out of warranty due to age misuse or damage shall be evaluated and a repair estimate shall be provided No repair work will be performed until a valid purchase order is received from the Customer and a Return Merchandise Authorisation number RMA is issued by DSC s Customer Service Digital Security Controls s liability for fai...

Page 10: ...ULA and provided the recipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC may terminate this EULA if You fail to comply with the terms and conditions of this EULA In such event You must destroy all copies of the SOFTWARE PRODUCT and all of it...

Page 11: ......

Page 12: ...ademarks not owned by Tyco are the property of their respective owners and are used with permission or allowed under applicable laws Product offerings and specifications are subject to change without notice Actual products may vary from photos Not all products include all features Availability varies by region contact your sales representative 2020 Tyco Security Products All rights reserved Johnso...

Reviews: