38
Insert the key when starting the PC094 for use.
To activate the Safety Override Switch, rotate the key
clockwise and hold it to disable ALL of the PC094
’
s
safeties and operator aids.
4. Emergency Stop Switch
To start and use the PC094, this switch should be in the
OFF position (raised).
To activate the Emergency Stop Switch, press down on
the button until it snaps into the ON position.
The Emergency Stop Switch will remain ON (engaged)
until the button is rotated counterclockwise until it rises
back into the OFF position.
5. Boom Telescope Control Lever
Untouched, the lever will reset to the center,
neutral position.
To telescope the boom out (BOOM OUT) push
the lever FORWARD.
To telescope the boom in (BOOM IN), pull the
lever BACK.
6. Winch Control Lever
Untouched, the lever will reset to the center,
neutral position.
To command the winch to lower the hook
block (WINCH DOWN), push the lever
FORWARD.
To command the winch to raise the hook block
(WINCH UP), pull the lever BACK.
7. Boom Angle Control Lever
Untouched, the lever will reset to the center,
neutral position.
To lower the boom (BOOM DOWN), push the lever FORWARD.
To raise the boom (BOOM UP), pull the lever BACK.
8. Charging Port
The Safety Bypass Switch with no key
inserted (left), with key inserted and
OFF (middle), and held in the ON
position (right)
The Emergency Stop Switch in ON
(left) and OFF positions (right)
In this image, the other controls and the cover have
been removed. These are the Crane Control Levers.
From the left to right, Boom Telescope Control
Lever, Winch Control Lever, and the Boom Angle
Control Lever.
Summary of Contents for SPYDERCRANE PC094
Page 1: ...Operator s Manual SPYDERCRANE PC094 Published July 2020...
Page 5: ...5 Chapter 1 GENERAL INFORMATION...
Page 13: ...13 1 Part Hook 1 900 lbs...
Page 14: ...14...
Page 21: ...21 GENERAL INFORMATION PC094 Travel and Lifting Performance Flowchart...
Page 35: ...35 Chapter 2 OPERATOR INSTRUCTIONS...
Page 65: ...65 Chapter 3 TROUBLESHOOTING...
Page 66: ...66 Troubleshooting Crane Controls are Unresponsive AND Percent Rated Load Indicator is RED...
Page 67: ...67 Troubleshooting Crane Does Not Travel...
Page 68: ...68 Troubleshooting Crane Does Not Turn...
Page 69: ...69 Troubleshooting No Hydraulic Response...
Page 70: ...70 Chapter 4 PREVENTATIVE MAINTENANCE...