4-44
6
Press
key. Then the adjustment
pattern shown in the figure below is
printed.
#TEST PRINTS
*
EXECUTING
media adv
anc
e dir
ec
tion
[LS ADJ PRINT] print sample
Blank area
Media f
eeding direc
tion
M
ed
ia
feeding direc
tion
Blank area
Measure the blank area with
15mm
as the reference value to obtain
the adjustment correction value.
• How to measure the “LS ADJ TOP VAL”
<Example>
When the blank area is
14mm
: The adjustment correction value will be
–1.0mm
.
When the blank area is
16mm
: The adjustment correction value will be
+1.0mm
.
Measure the length (blank area) between
the adjustment pattern and the cut
media.
• How to measure the “LS ADJ SIDE VAL”
•
How to calculate the adjustment correction value
Measure the length (blank area) between the
adjustment pattern and the edge of the media.
IP-5610取説_E.indb 44
09.4.3 3:15:32 PM