cordless.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
11-7
HiPath Cordless Office
Power-Related Capacity Limits
●
HiPath 3550 and HiPath 3500
The following tables show which telephone configurations do not need an additional power
supply:
–
Table 11-4, depending on the number of BS3/1 and BS4 base stations connected to
the central CBCC/CBRC control board.
–
Table 11-5, depending on the number of BS3/1 base stations connected to SLC16N
and the number of BS4 base stations connected to SLC16N.
–
Table 11-6, depending on the number of BS2/2 base stations connected to SLC16N.
–
Table 11-7, depending on the number of BS3/3 base stations connected to SLC16N
and the number of BS4 base stations connected to SLC16N.
If extra telephone configurations are added to these, an additional power supply (by
) is needed.
Table 11-4
HiPath 3550, HiPath 3500 - Maximum Number of Corded Telephones De-
pending on the Number of BS3/1 and BS4 Base Stations Connected to
CBCC or CBRC
Number
of BS3/1s and BS4s
connected via
1xU
P0/E
to
CBCC or CBRC
Maximum number of corded telephones
analog telephones
0
1 - 10
11 - 20
21 - 30
31 - 40
41 - 50
optiset E and optiPoint 500 telephones
1
66
61
57
53
48
44
2
63
59
54
50
46
41
3
60
56
52
47
43
39
4
58
53
49
45
40
36
5
55
51
47
42
38
33
6
53
48
44
40
35
31
7
50
46
41
37
33
28