HiPath 3350 Board Power Requirement
D.4
HiPath 3350 Board Power Requirement
Table D-7
Nominal Output of the HiPath 3350 Power Supply Units
Power Supply Unit
Part Number
Max. Nominal Output in W
5 V
–48 V
S30122-K5658-M
15.0
19.2
S30122-K5660-M300
20.0
1
1
Nominal output = 40 W. Due to build-up of heat, not more than 20 W may be withdrawn.
53.0
with
S30122-K5660-M300
with
S30122-K7221-X2
40.0
140.0
>
You must check whether the total power requirement of the boards used and the
connected workpoint clients exceeds the maximum possible output of the PSUP or
the UPSC-D with or without EPSU2. Section D.8 contains a sample calculation.
Table D-8
HiPath 3350 Board Power Requirement
Board or Component
Part Number
Net Power Requirement in
W
5 V
–48 V
S30807-H5482-X
–
2.0
S30807-H5485-X
–
3.0
(including submod-
ules)
S30810-Q2935-A301
7.0
0.5
S30817-Q951-Axxx
0.5
–
S30817-Q951-Axxx
0.5
–
S30817-Q951-Axxx
0.5
–
(including ventilator
kit)
S30810-Q2943-X 10.0
2.8
S30122-Q7379-X100
2.6
0.3
S30807-Q5692-X100
–
5.0
S30817-Q922-A301
0.8
–
S30817-Q924-B313
0.6
–
S30817-Q924-A313
1.0
–
S30817-Q932-A
0.5
–
S30817-Q923-Bxxx
0.1
–