Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-336
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Peripheral Boards
The operating mode (short or long line with the appropriate flash times) can be set up for each
subscriber line interface with HiPath 3000 Manager E (the menu settings: Set up station –> Sta-
tion –> Param –> Flags).
Figure 3-142
16SLA (Not for U.S.) - Interfaces (S30810-Q2923-X)
Table 3-161
16SLA (Not for U.S.) - Contact Assignments
Contact
X2
(T/R ports 1 to
4)
X3
(T/R ports 5 to
8)
X4
(T/R ports 9 to
12)
X5
(T/R
ports
13-
16)
1
a 1
a 5
a 9
a 13
2
b 1
b 5
b 9
b 13
3
a 2
a 6
a 1
a 14
4
b 2
b 6
b 10
b 14
5
a 3
a 7
a 11
a 15
6
b 3
b 7
b 11
b 15
7
a 4
a 8
a 12
a 16
8
b 4
b 8
b 12
b 16
T/R ports
1-4
Stns. 1 to 4
T/R ports
5-8
Stns. 5 to 8
X1
50
2
X2
X3
16SLA
1
8
1
8
X4
X5
1
8
1
8
T/R ports
9-12
Stns. 9 to 12
T/R ports
13-16
Stns. 13 to 16
To
CUP
CUC