Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-158
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Peripheral Boards
●
HiPath 3550
Subject to certain prerequisites, the system-internal PSU UPSC-D provides sufficient pow-
er for the operation of sixteen BS3/1s (one U
P0/E
each) or eight BS2/2s and BS3/3s (two
U
P0/E
each). These prerequisites depend on the
–
Line length and line type between SLC16N and base station.
The following specifications are based on line lengths of up to 1000 m and a line type
2x0.6 mm per U
P0/E
.
–
Number and type of corded telephones connected to the system.
Table 3-65 through Table 3-67 show which telephone configurations work without ad-
ditional power supply.
Table 3-65
HiPath 3550 - Maximum Number of Corded Telephones Depending on the
Number of BS3/1 Base Stations Connected to SLC16N and BS4 connect-
ed to SLC16N (not for U.S)
Number
of BS3/1s and BS4s
connected via 1xU
P0/E
to
SLC16N
Maximum number of corded telephones
analog telephones
0
1 - 10
11 - 20
21 - 30
31 - 40
41 - 50
optiset E and optiPoint 500 telephones
1
66
61
57
53
48
44
2
63
59
54
50
46
41
3
60
56
52
47
43
39
4
58
53
49
45
40
36
5
55
51
47
42
38
33
6
53
48
44
40
35
31
7
50
46
41
37
33
28
8
47
43
39
34
30
26
9
45
40
36
32
27
23
10
42
38
33
29
25
20
11
40
35
31
27
22
18
12
37
33
28
24
20
15
13
34
30
26
21
17
13
14
32
27
23
19
14
10
15
29
25
20
16
12
7
16
27
22
18
13
9
5