Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-152
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Peripheral Boards
3.3.12
SLC16N (Not for U.S.)
Introduction
The SLC16N board connects base stations for HiPath Cordless Office to
●
HiPath 3750 and HiPath 3700 (max. four SLC16Ns per system).
●
HiPath 3550 (max. one SLC16N per system).
Chapter 11 contains basic information on the options available for the use of HiPath Cordless
Office.
Base stations must be clocked with a high degree of accuracy for HiPath Cordless Office. Install
the plug-in
subboard on the
board (HiPath 3750 and HiPath 3700) or the plug-in
or
subboard on the
board (for HiPath 3550) to ensure clock accuracy (see
>
For initial installation of the HiPath Cordless Office, the HiPath cordless system num-
ber (DECT ID) must be ordered together with the SLC16N board.
Replacement boards are always delivered without a HiPath cordless system num-
ber.
Installing the SLC16N and entering the HiPath cordless system number releases 16
mobile units for use (PIN numbers are assigned). These mobile units can then be
logged on to the system. Any additional mobile units to be used must first be re-
leased (see Section 10.11.6).