boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-341
Boards for HiPath 3000
Options
Interfaces
ALUM module contact assignments
Figure 3-145
ALUM4 - Interfaces (S30817-Q935-A)
>
The cable that is plugged in by default is split and is connected to the TLA and to the
4/8/16SLA board.
Table 3-163
ALUM4 - Interface Assignments (Not for U.S.)
Contact
Connector X3
Connector X4
Connector X6
1
R1 from trunk 1a
AE1 to Stn. 1a
AT1 to TLA a
2
T1 from trunk 1b
BE1 to Stn. 1b
BT1 to TLA b
3
R2 from trunk 2a
AE2 to Stn. 2a
AT2 to TLA a
4
T2 from trunk 2b
BE2 to Stn. 2b
BT2 to TLA b
5
R3 from trunk 3a
AE3 to Stn. 3a
AT3 to TLA a
6
T3 from trunk 3b
BE3 to Stn. 3b
BT3 to TLA b
7
R4 from trunk 4a
AE4 to Stn. 4a
AT4 to TLA a
8
T4 from trunk 4b
BE4 to Stn. 4b
BT4 to TLA b
9
–
–
TA1 to SLA* a
10
–
–
TB1 to SLA* b
11
–
–
TA2 to SLA* a
12
–
–
TB2 to SLA* b
ALUM module
CB side
Board side
X1
X2
X3
X4
from the CO
to the
1
8
1
8
X6
1
16