service.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
12-55
Service
Guided Maintenance
14
Overload Code Receiver CR
–
Check if these errors oc-
cur repeatedly or only
sporadically. If the errors
occur repeatedly,
an additional CR8N board
can be used for HiPath
3750 and HiPath 3700.
An upgrade to the next
highest system may be
necessary for all other
systems.
15
Overload Code Sender CS
–
Error Class B-23 - Network
60
System hold no buffer available
Hard restart
Notify appropriate service
support
Error Class B-26 - Presence
0
Unknown card type
–
Replace board
1
Board out of order
Reload board
–
2
Maximum number of peripheral boards
exceeded
–
Reduce peripheral boards
to maximum number
3
Board type not compatible, slot is already
pre-assigned with a different board model
–
Replace board
4
Board is activated
–
–
Error Class B-28 - Recovery
0
COSMOS error: Data transmission not
possible
Hard restart
Notify appropriate service
support
Error Class B-29 - IOP
0
COSMOS error
Hard restart
Notify appropriate service
support
20
Port table queue is empty
Hard restart
24
Board malfunction
Reload board
–
25
Board reset was detected
Reload board
–
Table 12-7
HiPath 3000 Class B Error Messages
No.
Meaning
Action
Recovery
Action
Technician