
Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-370
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Options
Relay specifications
Electrical characteristics of the relays are as follows:
●
Operating voltage: 12 Vdc
●
Trunk failure transfer power consumption: 40 mA at 12 V nominal voltage
●
Power consumption per relay: 20 mA at 12 V nominal voltage
●
Trunk failure transfer contact load: 60 mA at -60 V nominal voltage
●
Maximum trunk failure transfer contact load with atmospheric influence: 8 A
●
Contact load for relays K1 to K4: 1 A with 250 Vac
●
Maximum current drain - 48 VF: 80 mA
Installation location of the REAL board (backplane)
The REAL board (basic cabinet only) is connected to the backplane using a ribbon cable (X05).
It is connected to the MDFU or MDFU-E or the patch panel using an SU cable connector X06.
Figure 3-164
Installation Location of the REAL Board
X05
X80
UPSM
X06
X70
07
REAL
with
connection
cable