Installing HiPath 3000
P31003-H3560-S403-54-7620, 09/05
4-182
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
inst_h3.fm
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Digital and analog trunks and subscriber lines from HiPath 3550 (wall housing)
>
The accessory pack does not contain enough ferrite sleeves for all trunks and sub-
scriber lines possible in a maximum system configuration. In this case, you will need
to order additional ferrite.
If
Then
Trunk board or
subscriber line
modules in Hi-
Path 3750 for-
mat
Guide both standard cables from SU X8 and SU X9 (see Figure 4-100) to
the MDFU through two ferrite sleeves (C39022-Z7000-C7) each. The ferrite
should be placed as far inside the housing as possible.
Trunk or sub-
scriber line
modules in
“small” format
Guide the trunk and subscriber lines of all ports connected on a board
through a ferrite sleeve twice, i.e. in a loop. The ferrite should be fixed in the
cable duct if possible. If the number of lines makes this impossible, the ferrite
can be attached directly at the output of the cable duct.