boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-215
Boards for HiPath 3000
Peripheral Boards
Interface Assignments (for U.S. only)
Note: The STLS4 module supports the trunk side in Europe, so the transmit and receive signals
must be reversed before the first device on the S
0
bus. In contrast, the optiset E ISDN adapter
uses a straight-through connection because it is always a station-only device. For information,
see Figure 3-88.
The ISDN terminals must have their own local power supply.
The system assigns the MSN only after the S
0
port is configured on the "Euro bus" (not for U.S.)
and can be read out via the administration (Assistant T: Code 20 4 3 S
0
Bus MSN).
Table 3-98
STLS4 Module Interface Assignments (For U.S. Only)
Pin
Port
Assignment
Pin
Port Assignment
2
1
Signal transmit
2
3
Signal transmit
3
Signal receive
3
Signal receive
4
Signal receive
4
Signal receive
5
Signal transmit
5
Signal transmit
2
2
Signal transmit
2
4
Signal transmit
3
Signal receive
3
Signal receive
4
Signal receive
4
Signal receive
5
Signal transmit
5
Signal transmit