boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-291
Boards for HiPath 3000
Peripheral Boards
Assignments for the two TMCAS cables for HiPath 3750, HiPath 3700, and HiPath 3550
You can use one of the following two cables to connect the network terminator NT, multiplexer
MUX, or modem to the TMCAS board:
●
symmetric line (120 ohms)
●
coaxial line (75 ohms)
Table 3-135
Assignment of the TMCAS Cable C39195-A9700-B512
SU connector Xx8, pin
Function
Color code
2
a-wire (T), receive
grn
22
b-wire (R), receive
blk
6
a-wire (T), transmit
red
26
b-wire (R), transmit
blk
Table 3-136
Assignment of the TMCAS Cable C39195-A9700-B514
SU connector Xx8, pin
Function
Wire
2
a-wire (T), receive
BNC shield, cable 1
22
b-wire (R), receive
BNC signal, cable 1
6
a-wire (T), transmit
BNC shield, cable 2
26
b-wire (R), transmit
BNC signal, cable 2