exup.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
9-29
Expanding and Upgrading HiPath 3000
Upgrading HiPath 3000 to V6.0
9.3
Upgrading HiPath 3000 to V6.0
The following information describes the measures that are needed to upgrade the hardware
and
software.
9.3.1
Hardware Upgrade
The following hardware requirements apply to HiPath 3000/5000 V5.0 and higher.
Contol Boards
If the control board necessary for operating HiPath 3000/5000 V5.0 and higher is not available,
a replacement must be performed.
For Deutsche Telekom AG only: The CBCP board S30810-Q2935-B201 must be replaced by
a CBCC board S30810-Q2935-A301.
Multimedia card MMC
An
with 64 MB is required to run HiPath 3000/5000 V5.0 and higher.
>
It is not possible to upgrade HiPath 3550 to HiPath 3500 or HiPath 3350 to HiPath
3300. This would require replacing the complete system.
System
Control board necessary for HiPath 3000/5000 V5.0 and higher
HiPath 3800
, S30810-Q2314-X and higher
HiPath 3750
HiPath 3700
, S30810-Q2936-X-J2 and higher
HiPath 3550
HiPath 3350
, S30810-Q2935-A301 and higher
HiPath 3500
HiPath 3300
, S30810-Q2935-Z301 and higher
>
Note for upgrading from hardware < version 1.2:
If the following subboards are present, they must be replaced:
(replaces the
/
(replaces the CGM/CGMC).