Expanding and Upgrading HiPath 3000
P31003-H3560-S403-54-7620, 09/05
9-12
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
exup.fm
Expanding HiPath 3000
9.2.4.2
Components
●
Expansion cabinet rack (ECR): S30777-U711-E901
The scope of delivery includes:
–
A mounting set for installing the ECR in a 19-inch cabinet: C39165-A7027-D1
–
A mounting clamp: D72571-A80-S3
–
A toothed lock washer: D6797-A43-S657
●
Mounting set for ECR wall installation or ECR table setup: C39165-A7027-D2
●
EPSU2-R: S30122-K7221-X900
A cable for making the ECR – HiPath 3500 or HiPath 3300 electrical connection is included
in the delivery: C39195-Z7001-C14
●
4 batteries, 12 V/7 Ah: 4 x V39113-W5123-E891
●
Connection cable, ECR (batteries) – HiPath 3700 (UPSM + power failure signaling (lamp-
wire connector): a relay connected in series can be used for signaling purposes, for exam-
ple.): C39195-A7002-B11
●
Connection cable, ECR – HiPath 3500 or HiPath 3300: S30267-Z361-A10
9.2.4.3
Installation Options
The expansion cabinet rack ECR can be
●
installed in a 19-inch cabinet (see Section 4.4.4.5).
●
mounted on a wall (see Section 4.4.4.4).
●
set up on a table using four adhesive mounting feet.
7
Caution
Both of the above-mentioned connection cables are system-specific.
●
C39195-A7002-B11 is exclusively designed for HiPath 3700.
●
S30267-Z361-A10 is exclusively designed for HiPath 3500 and HiPath 3300.
Failure to observe the above may damage the power supply unit.
>
Use the power cable to ground the ECR. Fixed, separate grounding is not required.