Starting Up HiPath 3000
P31003-H3560-S403-54-7620, 09/05
5-18
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
start_h3.fm
Starting Up HiPath 3750 and HiPath 3700
5.3.6
Customer-Specific Programming
You can program the system using one of the following tools:
●
Assistant T (programming telephone, see Appendix A)
●
HiPath 3000 Manager E (PC tool)
Refer to the HiPath 3000 Manager E Help for information on programming individual features.
5.3.7
Performing a System Check
Checking the telephones
●
The display must be checked on every telephone. The phone number, date and time are
normally shown in the display.
If a different text appears (“Gateway not found”, for example), this means that there is an
error.
Correct the error by following the administration instructions for the relevant telephone.
●
Perform random terminal tests as described in Section 12.3.1.8
on all telephones.
Checking for proper system booting
●
Set up internal and external calls at random to check if the system is functioning properly.
>
Changes to the system (for example key programming) made using during an HiPath
3000 Manager E offline programming session will be lost when the database is load-
ed.
When you program the system offline, the assignments of trunk and subscriber ports
depend on the order in which the boards are inserted. Usually, the boards are insert-
ed from the lowest slot to the highest.