boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-319
Boards for HiPath 3000
Peripheral Boards
LED statuses and their meanings
Table 3-153
TMST1 (for U.S. only) - LED Statuses
Red LED
Green
LED
Status
Activity
Off
Off
Board not receiving power or not plugged in
correctly.
Board is out of order.
Check plug contact on
board.
On
Off
Board is receiving power and board test is
in progress.
Board is defective if status remains un-
changed (board test unsuccessful).
Replace board.
Loadware loading not successfully com-
pleted. Board is faulty.
Replace board.
Error detected on board.
Board is deactivated (not applicable to er-
rors detected by test loops) or board was
deactivated using HiPath 3000 Manager E.
Check whether the board
was deactivated using Hi-
Path 3000 Manager E. If
not, replace board.
Flashing
Off
Loadware is being loaded.
Off
On
Board test completed successfully. Board is
OK (idle state).
Off
Flashing At least one subscriber line circuit is activat-
ed.
On
On
Board error
Replace board.