boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-157
Boards for HiPath 3000
Peripheral Boards
Supplying power to base stations
Power is supplied to the base stations primarily via the internal PSU in the system in question.
●
HiPath 3750 and HiPath 3700
The internal system power supply unit provides sufficient power to the configurations men-
tioned in Table 3-64.
For distances of up to 1000 m (at 2x0.6 mm) between the SLC16N and base station, the
BS2/2 and BS3/3 must each be connected via two U
P0/E
interfaces. Only one U
P0/E
inter-
face is required for BS3/1 base stations.
Table 3-64
HiPath 3750, HiPath 3700 - Maximum Number of SLA24N and SLMO24
User Groups (Depending on the Number of Base Stations Connected at
SLC16N (Not for U.S.)
HiPath 3750
HiPath 3700
Number of
SLC16N
Number of base stations
Number of
SLA24N
SLMO24
BS3/1
BS4
connected via
1xU
P0/E
BS2/2
BS3/3
BS4
connected via
2xU
P0/E
BC
0
0
0
7
1
16
8
5
2
32
16
3
Expansion cabinet
0
0
0
8
1
16
8
6
2
32
16
4
3
48
24
2
4
64
32
0