
boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-45
Boards for HiPath 3000
Central Boards
Switches and LEDs
LED statuses and their meanings
Figure 3-8
CR8N (S30810-Q2513-X100)
Table 3-22
CR8N - LED Statuses
Red LED
Green
LED
Status
Action
Off
Off
Board not receiving power or not plugged in
correctly.
Board is out of order.
Check plug contact on
board.
On
Off
Board is receiving power and board test is
in progress.
Wait
If the status does not change, the loadware
did not load correctly. Board is faulty.
Replace board.
Flashing
Off
Loadware is being loaded.
On
On
Board test unsuccessful, board is defective. Replace board.
Off
On
Board test completed successfully. Board is
OK (temporary transition).
Off
Flashing Board operational.
H1 (red)
H2 (green)
LEDs