TRBL
SHTG
Troubleshooting
9-25
6AL3J11
Symptom 1: PTT unit does not hold the outboard motor up
Troubleshooting the lower unit
Symptom 1: Shift mechanism of the forward gear and reverse gear does not operate properly
Symptom 2
Cause 1
Cause 2
Checking step
Refer
to
page
—
Manual valve
opened
Manual valve mal-
function
Check the manual
valve.
7-30
Insufficient PTT flu-
id
—
Add sufficient fluid.
3-13
PTT fluid leakage
—
Check the PTT unit
for leakage.
7-30
Clogged fluid pas-
sage
—
Disassemble and
check the PTT unit.
7-30
Symptom 2
Cause 1
Cause 2
Checking step
Refer
to
page
—
Remote control box
malfunction
—
Check the remote
control box.
1-24
Shift cable and shift
cable end malfunc-
tion
—
Check the shift ca-
ble and shift cable
end.
3-12
Adjust the shift ca-
ble.
3-12
Shift rod operation
malfunction
Detent malfunction
Check the detent.
7-1
Shift rod connec-
tion malfunction
Check the shift rod
connection.
6-5
6-34
Shift mechanism
malfunction (in low-
er unit)
—
Check the internal
parts of the lower
unit.
6-1
6-31