- 201 -
-
201
-
C
h
ap
ter
7
7-3
Description of Functions
Code No.
Function Name
Date Content
Setting
Resolution
Factory
Presets
F2303
F2304
F2305
LCD‘s 1st display parameter setting
LCD‘s 2nd display parameter setting
LCD‘s 3rd display parameter setting
0
:
No selection
1
:
Frequency [Hz]
2
:
Output current [A]
3
:
Speed [rpm]
4
:
Load factor [%]
5
:
Output voltage [V]
6
:
DC voltage [V]
7
:
Active power [kW]
8
:
Apparent power [kVA]
9
:
Radiator temperature [
℃
]
10
:
Command speed [rpm]
11
:
PID1 feedback value [Hz]
12
:
PID2 feedback value [Hz]
13
:
VIF1 analog input value
14
:
VIF2 analog input value
15
:
VIF3 analog input value
16
:
Output torque [%]
17
:
Excitation current [A]
18
:
Torque current [A]
19
:
Detecting position [mm]
32
:
Command frequency [Hz]
33
:
Command torque [%]
38 : Speed [rpm](subPG)(option)
42 : Target frequency[Hz]
43 : Output frequency[Hz]
44: DP control bit (option)
45: DP status bit (option)
1
1
2
4
● When LCD is connected, it‘s an effective function code.
F2306
LCD backlight off time
When no action on the operation panel is required, set the LCD backlight off time.
Code No.
Function Name
Date Content
Setting
Resolution
Factory
Presets
F2306
LCD backlight off time
0
:
off
1-600[minute(s)]
999
:
Normally on
1 min.
10
● When LCD is connected, it‘s an effective function code.
● When backlight is off, the display on LCD will also be eliminated.
● When F2306=0, the backlight of LCD is normally off. Therefore, there is no display on LCD.
● When F2306=999, LCD backlight will not be off.