7-3 Description of Functions
F1501
Internal analog output function 1
F1502
Internal analog output coefficient 1
F1504
Internal analog output function 2
F1505
Internal analog output coefficient 2
F1506
Internal analog output bias 2
Functions for analog output (0-10V) of a variety of internal states of inverter between the control circuit terminal‗s analog
output terminals AOUT1, AOUT2 and analog signal common terminal ACM.
Code No.
Function Name
Data Content
Setting
Resolution
Factory Presets
F1501
F1504
Internal analog output function 1
Internal analog output function 2
0:Inactive
1: Set frequency [Hz]
2: Output frequency [Hz]
3: PID1 feedback value [Hz]
4: PID2 feedback value [Hz]
5: Output current [A]
6: Output voltage [V]
7: DC voltage [V]
8: Radiator temperature [
℃
]
9: Load factor [%] (accumulated value of
the electric thermistor)
10: Load factor [%] (ratio to rated current)
11: VIF1 analog input value [V]
12: VIF2 analog input value [V]
13: VIF3 analog input value [V]
14: Speed [rpm]
15: Active power [kW]
16: Apparent power [kVA]
17: PID1 command value [Hz]
18: PID1 input deviation value [Hz]
19: PID2 command value [Hz]
20: PID2 input deviation value [Hz]
21-23: For factory adjustment
24: External PID1 output value [Hz]
25: External PID2 output value [Hz]
26: For factory adjustment
35: Command frequency [Hz]
36: Command torque [%]
39: Speed[rpm](subPG)(option)
40: Output torque [%]
99: For factory adjustment
1
0
0
F1502
F1505
Internal analog output coefficient 1
Internal analog output coefficient 2
0-20
0.01
1
1
F1503
F1506
Internal analog output bias 1
Internal analog output bias 2
0-±10V
0.1V
0
0
F1503
Internal analog output bias 1