- 165 -
C
h
ap
ter
7
7-3 Description of Functions
F1518
Low speed matching level
F1519
Low speed matching range
These functions are used to set torque level and torque matching range output by the torque matching signal.
Code No.
Function Name
Data Content
Setting
Resolution
Factory Presets
F1518
Low speed matching level
0-2,000 rpm
1rpm
100
Code No.
Function Name
Data Content
Setting
Resolution
Factory Presets
F1519
Low speed matching range
0-100 rpm
1rpm
10
If any one of F1509 – F1511 is 43 (low speed detection signal), the signal is output from control circuit output terminals
DO1 to DO3 when the detected speed matches the value set by F1518. The matching width is specified with the set value
of F1519. Similarly, for F1513, the signal can also be output from control circuit relay output terminals FA1, FB1 or FC1.
The low speed matching range is also used in forward run detection signal or reverse run detection signal for
multifunctional output.
F1523
Low torque order
This is the function set the command torque level to output the low torque command.
Code No.
Function Name
Data Content
Setting
Resolution
Factory Presets
F1523
Low torque order
0-200%
0.1%
0
If any one of F1509-F1511 is set "59", Control circuit output terminal "DO1-DO3"output signals when the torque
command was set on F1523.
In the same way, if F1513 is set "59", Control circuit relay output terminal "FA1, FB1,
FC1"output signals.
Summary of Contents for SVCO6
Page 1: ...High Performance Vector Control Inverter Instruction Manual SANKEN ELECTRIC CO LTD ...
Page 2: ......
Page 324: ... 322 Memorandum ...