9 | Menu | 9.5 | Audio System: The Global Audio Settings Menu
EN-160
SurroundControl 31900/31960 Series
The following options are available for the external refe-
rence source:
•
Monitoring Input
The monitoring input signal selected by the user is
used as external reference source.
• Auto
Search
This setting automatically polls the digital inputs for a
valid digital signal. As soon as a valid signal is found
it is used as the reference sync signal. If this signal is
no longer available the system polls the other inputs
until it fi nds a valid signal, and the digital inputs are
muted while this is being done.
•
Use Ref Input
Presets the system to the
Ref Sync IN
input connec-
tor (see
Connection
chapter).
NOTE -
No automatic search is performed
when this setting is activated! If there is no reference
sync signal, the digital input signals are no longer dis-
played and the analog input signals are only displayed
with a very narrow bandwidth.
•
Dig 3.12 to Dig 4.78
One of the eight available digital input pairs can be
selected so that its digital signals can be used as the
reference sync signal:
Dig 3.12
is AES input
1
of the
Digital 3 In/Out
connector, internal channels
1
and
2
;
Dig 3.34
is AES input
2
of the
Digital 3 In/Out
connector, internal channels
3
and
4
;
…;
Dig 4.56
is AES input
3
of the
Digital 4 In/Out
connector, internal channels
5
and
6
;
Dig 4.78
is AES input
4
of the
Digital 4 In/Out
connector, internal channels
7
and
8
NOTE -
No automatic search is performed
when this setting is activated! If there is no reference
sync signal, the digital input signals are no longer dis-
played and the analog input signals are only displayed
with a very narrow bandwidth.
•
Use SDI Input
If using the signal connected to the
SDI interface
,
the SDI source must always be the master.
•
Force reference source to SDI input if monitoring SDI
If one of the digital inputs, the
Auto Search
function or
the reference input is selected for the reference sour-
ce, with this option the unit can be forced to switch its
reference to the
SDI input
whenever monitoring a SDI
source. This option can be seen as a special version of the
Monitoring Input
option (see above) where the reference
source only follows the monitoring selection in case
SDI
is selected for monitoring. For all other monitoring sources
except SDI the unit will use the reference source selected
under
External Reference Source
(see above).
NOTE -
If
Monitoring Input
or
Use SDI Input
is
selected for the external reference source, this option of
course is not available.
•
A-D Samplerate Source
Using this option, it is possible to defi ne a separate sam-
ple rate source only for the A-D converters of the unit.
For example, this can be useful to synchronize the A-D
converters to the internal 96 kHz clock while the unit is
locked to a 48 kHz digital input signal.
•
A-D locked to internal samplerate
The A-D converters are always locked to the internal
reference selected for the unit.
NOTE -
Activating this option will disable the
downmix from a digital input source during the time
an analog source is selected for monitoring. Digital si-
gnals are synchronized to the closest available digital
sample rate.
•
A-D follows reference below
The A-D converters use the digital reference source
selected in the combo box now available below.
The following options are available:
• Auto
Search
This setting automatically polls the digital inputs
for a valid digital signal. As soon as a valid signal
is found it is used as the reference sync signal. If
this signal is no longer available the system polls
the other inputs until it fi nds a valid signal, and
the digital inputs are muted while this is being
done.
•
Use Ref Input
Presets the system to the
Ref Sync IN
input.
Summary of Contents for SurroundControl 31960 Series
Page 1: ...SurroundControl 31960 Manual...
Page 2: ...SurroundControl 31960...
Page 3: ...DE SurroundControl 31960 Serie Bedienungsanleitung...
Page 12: ...Inhaltsverzeichnis DE 10 SurroundControl 31960 Serie...
Page 217: ...EN SurroundControl 31960 Series Operating Manual...
Page 226: ...Content EN 10 SurroundControl 31960 Series...
Page 252: ...6 First Use 6 13 Using Loudness Display Options EN 36 SurroundControl 31900 31960 Series...
Page 268: ...7 Control 7 3 External control via GP IO connector EN 52 SurroundControl 31900 31960 Series...