EN-149
9 | Menu | 9.4 | Input/Output Routing: The Global Routing Settings
EN
SurroundControl 31900/31960 Series
•
Standard Settings Digital
This combo box applies to the parameters grouped direct-
ly below it.
After selecting
Digital
,
ARD
or
True Peak
, these combo
boxes are automatically set to values corresponding to the
Digital
,
ARD
or
True Peak
standards. After editing any
of these combo boxes manually (except the
Operation
indicator area
combo box), the text „Non Standard“ is
displayed in the
Standard Settings Digital
combo box.
Reselecting
Digital
,
ARD
or
True Peak
automatically re-
sets all parameters grouped below to the standard values
of these presets.
• Scale
This combo box is used to select the preferred scale:
•
TP60
(–60 dBFS to +3 dBFS,
Standard Settings
Digital
, selection:
True Peak
)
•
TP20
(–60 dBFS to +3 dBFS)
•
Dig60dB
(–60 dBFS to 0 dBFS,
Standard Settings
Digital
, selection:
Digital
)
•
Dig20dB
(–20 dBFS to 0 dBFS)
•
Dig+18 dB... 0 dB
(0 dBFS = +18 dB)
•
Dig+18 dB... 0... –18 dB
(0 dBFS = +18 dB)
•
Dig+20 dB... 0... –40 dB
(0 dBFS = +20 dB)
•
ARD +9 dB... –60 dB
(0 dBFS = +9 dB,
Standard
Settings Digital
, selection
ARD
)
•
<q> DIN 5 dB
(quasi-DIN scale, –9 dBFS = 0 dB)
•
<q> DIN 10 dB
(quasi-DIN scale, –9 dBFS = 0 dB)
•
<q> ARD +9 dB... –60 dB
(quasi-DIN scale,
0 dBFS = +9 dB)
•
<q> Zoom +/– 10 dB
(quasi-DIN scale,
–9 dBFS = 0 dB)
•
<q> Zoom +/– 1 dB
(quasi-DIN scale,
–9 dBFS = 0 dB)
•
<q> Nordic
(quasi-Nordic scale, –9 dBFS = +6 dB)
•
<q> British IIa
(quasi-British scale,
–10 dBFS = “6”)
•
<q> British IIb
(quasi-British scale,
–10 dBFS = +8 dB)
• Integration
time
This combo box is used to select the integration time of
the level display:
•
10 ms (
Standard Settings Digital
, selection
ARD
)
• 20
ms
• 1
ms
• 0.1
ms
• Sample
(
Standard Settings Digital
, selection
Digital
)
• 150
ms
• DC-Filter
This combo box sets the DC fi lter. You can switch the fi lter
off (
Off
) or set it to
5 Hz
(standard settings digital),
10 Hz
or
20 Hz
.
• Headroom
This list box sets the beginning of the headroom in the
range between –20 dBFS and 0 dBFS. The digital stan-
dard setting is
–9 dBFS.
NOTE -
The headroom of the
ARD +9 dB...–60
dB
scale is fi xed to
–9 dBFS
. Choosing a different value
in the
Headroom
list box has no effect.
•
Operation indicator area
This list box sets the area where the indicator for the ope-
rating area is activated. Values between –20 dB and 0 dB
are available. The digital standard setting is
0 dB
.
•
Peak Hold fallback time
This combo box is for setting the hold time for the peak
hold display. Options:
1 s,
2 s
,
4 s
,
10 s
,
20 s
,
30 s
and
Manual Reset
. With
Manual Reset
selected, you can
reset the peak hold display with the
Reset
function in the
Loudness Meter.
• Mode
This combo box is used for switching the Peak Hold func-
tion on or off. Options:
Normal
,
Peakhold
.
• Bar
Style
This combo box selects the way the
PPM
and
Loudness
bargraphs are combined in the
Program Meter
display.
Options:
Lo U-Type PPM
(narrow PPM bar-
graphs left and right of the loudness bargraph),
Loudness
+ PPM Spot
(PPM spots left and right of the loudness
bargraph), and
Loud + PPM Dual
(PPM and loudness
bargraphs of same width side by side).
• Peakhold
enabled
These check boxes are used to activate the
Peakhold
displays for the
PPM
and
Loudness
bargraphs. Available
options:
PPM
(for peakmeter bargraphs),
Loudness
(for
loudness bargraphs).
Loudness ...
•
Operation indicator area
This list box sets the area where the indicator for the ope-
rating area is activated. Values between –20 dB and 0 dB
can be entered. The digital standard setting is
0 dB
.
• Numeric
This option is used to activate numerical displays for the
PPM
or
Loudness
bargraphs. Options:
Off
,
PPM
,
Loud-
ness
.
Summary of Contents for SurroundControl 31960 Series
Page 1: ...SurroundControl 31960 Manual...
Page 2: ...SurroundControl 31960...
Page 3: ...DE SurroundControl 31960 Serie Bedienungsanleitung...
Page 12: ...Inhaltsverzeichnis DE 10 SurroundControl 31960 Serie...
Page 217: ...EN SurroundControl 31960 Series Operating Manual...
Page 226: ...Content EN 10 SurroundControl 31960 Series...
Page 252: ...6 First Use 6 13 Using Loudness Display Options EN 36 SurroundControl 31900 31960 Series...
Page 268: ...7 Control 7 3 External control via GP IO connector EN 52 SurroundControl 31900 31960 Series...