Quick start
Quick start
When you’ve made the correct connections, check the REAC connections as follows.
1.
Power up the M-400 first, then the input/output units, and wait until the M-400 starts up.
2.
Press the M-400’s [SYSTEM] to access the System screen.
fig.ScrSystem.eps
3.
Press [F2 (REAC CONFIG)].
fig.ScrREACConf.eps
The REAC CONFIG popup will appear.
4.
Press [F2 (REAC A)] to access the REAC A tab, and verify that the name of the input/output unit connected
to REAC port A is shown.
5.
Verify the same for the REAC B tab ([F3 (REAC B)]).
6.
Press [F8 (CLOSE)] to close the popup.
If the input/output units connected to the REAC ports are not detected correctly, check the M-400’s REAC setting
(p. 186), the REAC settings of the input/output units, the connections of the Cat5e cables, and the conductivity of
the Cat5e cables.
Checking the REAC connections
M-400_v15_e.book 26 ページ 2008年6月20日 金曜日 午後4時5分