Maintenance and Service
Diesel engine
384 / 564
7.1.4.3
Replacing coolant
Use only corrosion protection/antifreeze agents approved by Volvo. The coolant must
be changed every 8000 operating hours, but at least every 4 years. In any case, com-
ply with the regionally applicable regulations on environmentally compatible disposal
of coolant.
1
(1)
Drain valve for coolant at cooling water pipe
Before renewal of coolant, check the cooling and heating system for leaks and condi-
tion.
The drain valve is on the coolant pipe (see picture).
– Slowly open the filler cap at the expansion tank of engine cooling system, relieve
excess pressure, then take off the cap.
– Screw on drain hose on the drain valve.
– Drain coolant and catch coolant in a suitable vessel.
– Close drain valve again.
– Fill in coolant in the prescribed combination up to the lower edge of the filling neck
and close the cover lid.
– Set the desired temperature for the air conditioning system to the maximum tem-
perature, so that the control valve for the heating system is opened.
– Start diesel engine and let it run for about 1 minute at differing rotational speeds.
– Check the coolant level and, in case of need, fill up coolant.
– Have replacement of coolant confirmed in service documentation.
Anticorrosion/antifreeze
:
Volvo Penta Coolant VCS (yellow)
Filling volume:
approx. 60 litres
Summary of Contents for Tiger 6
Page 3: ...Contents 3 564 Contents...
Page 4: ...Contents 4 564...
Page 13: ...Preface 13 564 1 Preface...
Page 14: ...Preface 14 564...
Page 22: ...Safety 22 564...
Page 23: ...Safety 23 564 2 Safety...
Page 24: ...Safety 24 564...
Page 41: ...General View and Specifications 41 564 3 General View and Specifications...
Page 42: ...General View and Specifications 42 564...
Page 53: ...General Description 53 564 4 General Description...
Page 54: ...General Description 54 564...
Page 57: ...Operating Components 57 564 5 Operating Components...
Page 58: ...Operating Components 58 564...
Page 98: ...Operation 98 564...
Page 99: ...Operation 99 564 6 Operation...
Page 100: ...Operation 100 564...
Page 226: ...Operation Defoliator 226 564 RIS defoliator RES defoliator...
Page 291: ...Operation Infeed conveyor 291 564 2 1 1 Infeed conveyor control block...
Page 299: ...Operation Strainer wheels turbines 299 564 4 Rpm strainer wheels...
Page 325: ...Operation Bunker unloading 325 564 6 19 Bunker unloading...
Page 361: ...Maintenance and Service 361 564 7 Maintenance and Service...
Page 362: ...Maintenance and Service 362 564...
Page 418: ...Maintenance and Service Defoliator 418 564 Defoliator in the maintenance position...
Page 475: ...Malfunction and Remedies 475 564 8 Malfunction and Remedies...
Page 476: ...Malfunction and Remedies 476 564...
Page 528: ...Lists Tables Plans Diagrams Maintenance Verification 528 564...
Page 558: ...558 564...
Page 559: ...Index 559 564 10 Index...
Page 560: ...Index 560 564...