154
Outside Line Outgoing Number
The SP sets the number that switches to PSTN for the outside connection for embedded RCG-
M in a system that employs a PBX (internal line).
• If the execution of SP5816-151 has succeeded and embedded RCG-M has connected
to the external line, this SP display is completely blank.
• If embedded RCG-M has connected to an internal line, then the number of the
• connection to the external line is displayed.
• If embedded RCG-M has connected to an external line, a comma is displayed with
• the number. The comma is inserted for a 2 sec. pause.
• The number setting for the external line can be entered manually (including commas).
156
Dial Up User Name
Use this SP to set a user name for access to remote dial up. Follow these rules when setting a
user name:
• Name length: Up to 32 characters
• Spaces and # allowed but the entire entry must be enclosed by double quotation marks
(").
157
Dial Up Password
Use this SP to set a password for access to remote dial up. Follow these rules when setting a
user name:
• Name length: Up to 32 characters
• Spaces and # allowed but the entire entry must be enclosed by double quotation marks
(").
161
Local Phone Number
Use this SP to set the telephone number of the line where embedded RCG-M is connected.
This number is transmitted to and used by the Call Center to return calls.
Limit: 24 numbers (numbers only)
Group 5000
343
4
Summary of Contents for V-C3 D081
Page 1: ...Model V C3 Machine Code D081 D082 Field Service Manual 30 November 2009...
Page 2: ......
Page 46: ...44...
Page 52: ...Overview Main Machine 1 Transport Belt ARDF 18 Grip Roller 1 Product Information 50 1...
Page 54: ...1 Product Information 52 1...
Page 135: ...19 Input 5 for B4 SEF or 6 for 8 5 x 14 SEF LG Size Tray Type 1075 B474 133 2...
Page 283: ...PM Tables See Appendices for the following information PM Tables PM Tables 281 3...
Page 284: ...3 Preventive Maintenance 282 3...
Page 326: ...4 Replacement and Adjustments 324 4...
Page 455: ...Left Lower Cover Removed AC Drive Board Boards 453 4...
Page 460: ...PFB 1 Remove the PFB A x14 x6 4 Replacement and Adjustments 458 4...
Page 461: ...HVPS 1 Remove the HVPS x4 x8 Charge Roller Power Pack Boards 459 4...
Page 463: ...DRB 1 Remove the DRB x14 x5 Boards 461 4...
Page 464: ...DTMB 1 Remove the DTMB x7 x4 4 Replacement and Adjustments 462 4...
Page 504: ...4 Remove the ITB drive motor A x4 x1 4 Replacement and Adjustments 502 4...
Page 508: ...2 Remove A Air filters B Ozone filter 4 Replacement and Adjustments 506 4...
Page 528: ...5 System Maintenance 526 5...
Page 568: ...Service Call Tables See Appendices for Service Call Tables information 6 Troubleshooting 566 6...
Page 572: ...Total 32 20 7 Energy Saving 570 7...
Page 575: ...6 Duplex with combine mode SP 8421 005 pages Paper Save 573 7...
Page 576: ...7 Energy Saving 574 7...
Page 577: ...Model V C3 Machine Code D081 082 Appendices 25 December 2009...
Page 578: ......
Page 647: ...3 Apply a thin layer of Grease KS660B around the surface at B as shown Lubrication Points 69 2...
Page 648: ...2 Appendix PM Tables 70 2...
Page 958: ...25 SDK J Application Info 4 Appendix Service Program Mode Tables 380 4...
Page 1092: ...4 Appendix Service Program Mode Tables 514 4...