These SPs set the paper size correction coefficient for the image to paper transfer bias threshold
values calculated based on the reading of the absolute humidity from the temperature/humidity
sensor and the thresholds set with SP2304.
SP2440 – Up to SP2304 001: Threshold 1
SP2441 – More than SP2304 001 Threshold 1, up to SP23204 002 Threshold 2.
SP2442 – More than SP2304 002 Threshold 2, up to SP2304 003 Threshold 3
SP2443 – More than SP2304 003 Threshold 3, up to SP2304 004 Threshold 4
SP2444 – More than SP2304 004 Threshold 4, up to SP2305 005 Threshold 3
SP2445 – More than SP2304 005 Threshold 5
These settings apply 1) only where the image is created in full-color on plain paper at full speed.
1 ITB
[10 to 200/ 1%]
17 Side1:PTR
18 Side1:SepDC
19 Side1:SepAC
27 Side2:PTR
28 Side2:SepDC
29 Side2:SepAC
275
1
Sp1 K Bias
Set Bias for Special Paper 1: K. These SPs set the standard values of the electrical charges that
are applied to 1) create bias for image transfer from drum to ITB, 2) create bias for image transfer
from ITB to paper (PTR), and 3) neutralize the charges on the both sides of the paper to separate
the paper from the ITB (SepDC, SepAC). These settings are used when printing on Special Paper
1 in the black-and-white mode and are applied only to the image area.
1 ITB
[0 to 70/0.1
μ
a]
7 Side1:PTR
[-100 to 0/1
μ
a]
8 Side1:SepDC
[0 to 10/0.1
μ
a]
9 Side1:SepAC
[8 to 12/0.1 kV]
12 Side2:PTR
[-100 to 0/0.1
μ
a]
4. Appendix: Service Program Mode Tables
224
4
Summary of Contents for V-C3 D081
Page 1: ...Model V C3 Machine Code D081 D082 Field Service Manual 30 November 2009...
Page 2: ......
Page 46: ...44...
Page 52: ...Overview Main Machine 1 Transport Belt ARDF 18 Grip Roller 1 Product Information 50 1...
Page 54: ...1 Product Information 52 1...
Page 135: ...19 Input 5 for B4 SEF or 6 for 8 5 x 14 SEF LG Size Tray Type 1075 B474 133 2...
Page 283: ...PM Tables See Appendices for the following information PM Tables PM Tables 281 3...
Page 284: ...3 Preventive Maintenance 282 3...
Page 326: ...4 Replacement and Adjustments 324 4...
Page 455: ...Left Lower Cover Removed AC Drive Board Boards 453 4...
Page 460: ...PFB 1 Remove the PFB A x14 x6 4 Replacement and Adjustments 458 4...
Page 461: ...HVPS 1 Remove the HVPS x4 x8 Charge Roller Power Pack Boards 459 4...
Page 463: ...DRB 1 Remove the DRB x14 x5 Boards 461 4...
Page 464: ...DTMB 1 Remove the DTMB x7 x4 4 Replacement and Adjustments 462 4...
Page 504: ...4 Remove the ITB drive motor A x4 x1 4 Replacement and Adjustments 502 4...
Page 508: ...2 Remove A Air filters B Ozone filter 4 Replacement and Adjustments 506 4...
Page 528: ...5 System Maintenance 526 5...
Page 568: ...Service Call Tables See Appendices for Service Call Tables information 6 Troubleshooting 566 6...
Page 572: ...Total 32 20 7 Energy Saving 570 7...
Page 575: ...6 Duplex with combine mode SP 8421 005 pages Paper Save 573 7...
Page 576: ...7 Energy Saving 574 7...
Page 577: ...Model V C3 Machine Code D081 082 Appendices 25 December 2009...
Page 578: ......
Page 647: ...3 Apply a thin layer of Grease KS660B around the surface at B as shown Lubrication Points 69 2...
Page 648: ...2 Appendix PM Tables 70 2...
Page 958: ...25 SDK J Application Info 4 Appendix Service Program Mode Tables 380 4...
Page 1092: ...4 Appendix Service Program Mode Tables 514 4...