b1.01
Saving options of digital set frequency
Factory default 0
Setting range
0 − 3
Minimum unit
1
●
0: Not saved in [b1.04] when powered off or stopped
●
1: Not saved in [b1.04] when powered off; saved when stopped
●
2: Saved in [b1.04] when powered off; not saved when stopped
●
3: Saved in [b1.04] when powered off or stopped
b1.02
Converter control commands
Factory default 0
Setting range
0, 1, 2
Minimum unit
1
●
0: Set control commands via operating panel
–
Use operating panel keys (Run, Stop and Jog) to control the fre‐
quency converter.
●
1: Set control commands via external terminals
–
Use external terminals (X0 – X7) to control run, stop, forward or re‐
verse. See also parameters in group E0.
●
2: Set control commands via communication
–
See the instructions for communication in
If [b1.02]=1 or 2, the Stop key on the operating panel can be ena‐
bled with [S3.15].
b1.03
Control mode
Factory default 0
Setting range
0, 1, 2
Minimum unit
1
●
0: V/F control (V/F)
–
Select this mode if it is impossible to conduct auto-tuning or obtain
accurate motor parameters.
–
V/F control without pulse encoder: is used to drive multiple
motors with one frequency converter.
–
V/F control with pulse encoder: is used when high accuracy of
speed control is required. See parameters [S2.12] − [S2.15]
for related settings.
In V/F control mode, set control parameters in group S0.
●
1: Sensorless vector control (SVC)
–
For high performance applications where no pulse encoder is nec‐
essary and high low-frequency torque and high accuracy of speed
control are required.
●
2: Field oriented vector control (FOC)
–
For high accuracy applications with speed and torque control. A
pulse encoder is necessary. See parameters [S2.12] − [S2.15] for
related settings.
DOK-RCON02-FV*********IB01-EN-P
Rexroth Frequency Converter Fv
Bosch Rexroth AG
91/219
Parameter Settings
Summary of Contents for Fv Series
Page 20: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 18 219...
Page 30: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 28 219...
Page 34: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 32 219...
Page 52: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 50 219...
Page 58: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 56 219...
Page 144: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 142 219...
Page 164: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 162 219...
Page 180: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 178 219...
Page 214: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 212 219...
Page 216: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 214 219...
Page 220: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 218 219...
Page 221: ...Notes DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv Bosch Rexroth AG 219 219...