Group b1: Basic Parameters
Type
Function
code
Name
Setting range
Minimum
unit
Factory
default
Attribute
Basic
parame‐
ters
b1.00
Frequency
setting
mode
0: Set by operating panel potentiometer
1: Set by operating panel
2: Set by external analog terminals
3: Set by pulse frequency
4: Set by external Up/Down terminals
5: Set via communication
1
0
◆
b1.01
Saving options
of digital set
frequency
0: Not saved when powered off or stopped
1: Not saved when powered off; saved when
stopped
2: Saved when powered off; not saved when
stopped
3: Saved when powered off or stopped
1
0
◆
b1.02
Converter
control commands
0: Set control commands via operating pan‐
el
1: Set control commands via external termi‐
nals
2: Set control commands via communication
1
0
◆
b1.03
Control mode
0: V/F control (V/F)
1: Senseless vector control (SVC)
2: Field oriented vector control (FOC)
1
0
◆
b1.04
Digital set frequency
b1.07 − b1.06
0.01 Hz
50.00 Hz ◇
b1.05
Maximum frequency
50.00 − 400.00 Hz
0.01 Hz
50.00 Hz ◆
b1.06
Upper limit frequency
b1.07 − b1.05
0.01 Hz
50.00 Hz ◇
b1.07
Lower limit frequency
0.00 − b1.06
0.01 Hz
0.00 Hz
◇
b1.08
Operating panel
controlled direction
0: Forward rotation
1: Reverse rotation
1
0
◇
Acc.
Dec.
time
and
modes
b1.09
Acceleration time 1
0.1 − 3600.0s
0.1s
10.0 s
◇
b1.10
Deceleration time 1
0.1 − 3600.0s
0.1s
10.0 s
◇
b1.11
Acceleration/deceleration
mode
0: Linear mode
1: S-curve mode
1
0
◆
b1.12
Time of S-curve
rising section 1
0.0 % − 40.0 %
(of ‘Acceleration time 1’ [b1.09])
0.1 %
20.0 %
◆
b1.13
Time of S-curve
rising section 3
0.0 % − 40.0 %
(of ‘Acceleration time 1’ [b1.09])
0.1 %
20.0 %
◆
b1.14
Time of S-curve
falling section 4
0.0 % − 40.0 %
(of ‘Deceleration time 1’ [b1.10])
0.1 %
20.0 %
◆
b1.15
Time of S-curve
falling section 6
0.0 % − 40.0 %
(of ‘Deceleration time 1’ [b1.10])
0.1 %
20.0 %
◆
Bosch Rexroth AG
DOK-RCON02-FV*********IB01-EN-P
Rexroth Frequency Converter Fv
70/219
Parameter Settings
Summary of Contents for Fv Series
Page 20: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 18 219...
Page 30: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 28 219...
Page 34: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 32 219...
Page 52: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 50 219...
Page 58: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 56 219...
Page 144: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 142 219...
Page 164: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 162 219...
Page 180: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 178 219...
Page 214: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 212 219...
Page 216: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 214 219...
Page 220: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 218 219...
Page 221: ...Notes DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv Bosch Rexroth AG 219 219...